PRESSURE CALIBRATION AND TESTING SYSTEMS
|
MANUAL PNEUMATIC PRESSURE PUMP Generated pressure: 0...35 bar
Generated vacuum: -0.95 bar
Connection terminal for reference instrument: G 1/2" -internal thread or G1/4" – external thread
Connection terminal for reference instrument: G1/4"– internal thread
Materials: aluminium, brass, ABS
Fine adjustment: adjustment valve
Dimensions: approximately 220 x 105 x 63 mm
Mass: approximately 510 g
|
|
|
MANUAL HYDRAULIC PRESSURE PUMP
Generated pressure: 0...700 / 0...1000 bar
Connection terminal for reference instrument: G 3/8"– internal thread
Connection terminal for reference instrument: G1/4" – internal thread
Working fluid: mineral oil or distilled water
Dimensions: appr. 236 x 159 x 70 mm
Mass: appr. 1.6 kg
Optionally: high pressure hose, 7 reductions set
|
|
HYDRAULIC COMPARISON PUMP
Generated pressure: 0...700 / 0...1400 bar
Connection terminal for reference instrument: G 3/8" – internal thread
Connection terminal for reference instrument: G 1/2" – internal thread
Working fluid: mineral oil or distilled water
Dimensions: appr. 236 x 159 x 70 mm
Mass: appr. 1.6 kg
Optionally: high pressure hose, 7 reductions set
|
|
|
Calibration system
-
pneumatic pressure pump
-
transport bag with analogue manometer, ±1.0% FS
|
|
Calibration system
-
pneumatic pressure pump
-
transport bag with digital manometer, ± 0.5% FS
|
|
Calibration system
-
pneumatic pressure pump
-
transport bag with digital manometer, ± 0.1% FS
|
|
Calibration system
-
pneumatic pressure pump
-
transport bag with digital manometer, ± 0.05% FS
|
|
PRESSURE PORTABLE CALIBRATOR
-
Internal sensors, with detection range -1...+400 bar
-
External sensors, with detection range -1...+700 bar
-
128 x 64 pixels display
-
Current and voltage measurement; selectable measurement units
|
|
PRESSURE CALIBRATOR
– Internal sensors, with detection range -1 … + 1000 bar
– Measurement and simulation: pressure, current, voltage
– PC communication facility via RS232 serial interface.
– current and voltage measurement; selectable measurement units
The device is dedicated to testing and calibration of the following types of equipment: pressure transducers and transmitters, pressure indicators (analog and digital), pressure-current converters or pressure-voltage converters, pressure control valves.
|
|
PRESSURE CALIBRATOR
– Pressure range: 0/250 mbar up to 0/1000 bar
– Interchangeable reference sensors
– All standard pressure measurement units (+ 1 set by the user)
– Special fields (relative pressure, absolute pressure, vacuum), on request
– Storage of calibration data
– English language menu (other languages, e.g. German, on request)
– Lithium-Ion battery supply
– 24 V d.c. supply for pressure transducers
– USB and RS232 interface
– Included calibration certificate
|
|
MULTIFUNCTIONAL CALIBRATOR
– Measurement/Simulation: pressure, vacuum, voltage, current, frequency, thermoresistances, thermocouples
– All standard pressure measurement units
– PC communication facility via RS232 serial interface
– 1 or 2 internal pressure sensors
– External sensors in different ranges, up to 700 bar
– English language menu (other languages, e.g. German, on request)
– Embedded pressure pump, up to 21 bar
|
|
MULTIFUNCTIONAL PORTABLE CALIBRATORS
– Functions: simultaneous generation and measurement of signals, testing of pressure control valves and thermostats, percentage scaling of measuring range, displaying in different measuring units, statistical functions, synthesis function
– Measurement quantities: voltage, current, resistance, temperature (thermoresistances and thermocouples), pressure, frequency
– Display: numerical and graphical
– Accuracy class: 0.02 / 0.01% (according to model)
– Compatibility: HART protocol
– Data storage capacity: 10000 values
– Stored configurations capacity: up to 10 instrument recalling configurations
– Number of channels: 2
– Software: PC dedicated data transfer capability.
|
|
PORTABLE THERMOMETER
– Function: measurement
– Sensors used: thermocouple and thermoresistance
– Display: numerical and graphical
– Measurement quantities: temperature, resistance, voltage
TEMPERATURE PORTABLE CALIBRATOR
– Function: signal measurement and generation
– Sensors used: thermocouple and thermoresistance
– Display: numerical and graphical
– Measurement quantities: temperature, resistance, voltage
|
|
PORTABLE PROCESS CALIBRATOR
– Function: automation loop control
– Input signal: 50V and 50mA
– Output signal: 15V and 24mA
– Function: measurement and simulation of quadratic current signal
– Communication capability: HART compatibility
– Generated signals: ramp and step
|
|
LABORATORY MICRO-OHMMETERS
– Resistance measurements on inductive and resistive loads
– Resistance measurement range: 0.1 … 2500 [O]
– Current range: 100mA … 10A d.c.
– Accuracy class: 0.05% + 5 digits
– Storage capability: 1000 values
– Generated signals: ramp and step
|
|
MODULAR DATA ACQUISITION SYSTEMS
– Functions: measurement, monitoring, storing, data processing
– Number of channels: 10 … 300 channels
– Communication: Ethernet, RS232, radio
– Input: analog or digital signal
– Software functions: configuration, acquisition, real time supervision
– Generated signals: ramp and step
|
|
|
|
|
|
|
|